Evaluation of a carbon paste electrode modified with Ionic liquid and MnO nanoparticles in the Cu(II)determination by Potentiometric Method

Mona Mosazadeh, Mahmoud Ebrahimi, Ali Morsali

Abstract


A chemically modified carbon paste electrode with ionic liquid and MnO nanoparticles was prepared and used as a sensor for Cu2+ ion. Theionic liquid and MnO nanoparticles were used in the composition of the carbon paste to improve conductivity and transduction of chemical signal to electrical signal. Moreover, incorporation of N,N',N"- Tricyclohexil phosphoric triamid as an ionophore to this composition caused to significantly enhanced selectivity toward Cu (II) ions. The electrode exhibit a super Nernstian slope of 29.9 ±0.25 mV per decade for Cu2+ ion over a wide concentration range from 1.0×10-1to 1.0×10-6M.The lower detection limits are 3.2×10 -7 M. The electrode has a fast response time (<6 s), a satisfactory reproducibility and relatively long life time. The proposed sensor shows a fairly good selectivity toward Cu2+ ion in comparison to other common cations and the working pH range was 4.0- 11. Finally, these electrode have been successfully applied for the determination of Cu2+ ions content in various real samples.

 

Keywords: copper, Carbon paste electrode, Ionic liquid, Potentiometric, Mnonanopartcles


Full Text:

PDF

References


J. Ruzicka, J.C. Tjell, Anal. Chim.Acta.1970; 49, 349.

J. Ruzicka, J.C. Tjell, Anal. Chim.Acta.1970; 51, 1.

J. Ruzicka, K. Rald, Anal. Chim.Acta.1971; 53, 1.

N.N. Greenwood, A. Earnshow, Handbook of Chemistry of the Elements, Pergamon Press,New York, 1984.

H.R. Marston, Physiol. Rev. 1952; 32, 56.

M. Akhond, M.B. Najafi, H. Sharghi, J.Tashkhourian, H. Naiemi, J. Chin. Chem. Soc. 2007; 54,331-337.

M. Mazloum-Ardakani et al./ JNS. 2012; 2, 333.

R. P. Buck, E. Lindner, Pure Appl. Chem. 1994; 66, 2527.

Y. UMEZAWA et al، Pure Appl. Chem., 2000; 72, 1851.

M.B. Gholivand, N. Nozari, Talanta, 2001; 54, 597.

N. Yamato, Y. Nagasawa, S. Shuto, M. Sawal, T.Sudo, H. Tsubomura, Chem. Lett.1978; 245.

N. Yamamoto, Y. Nagasawa, S. Shuto, M. Sawal, T.Sudo, H. Tsubomura, J. Immunol.Methods, 1978; 22, 309.

H.A. Laithinen, T.M. Hseu, Anal. Chem. 1979; 51, 1550.

W.R. Heineman, H.J. Wieck, A.M. Yacynych, Anal.Chem. 1980; 52, 345.

K. Vytras, J. Jezkova, J. Skorepa, Talanta, 1998; 46, 1619.

Z. Stanic, T. Dimic, Z. Simic, Lj N. Jaksic, S. Girousi, Polyhedron, 2011; 30, 702.

Z. Stanic, S. Girousi sensing in electroanalysis, 2011; 6, 89.

H. Ibrahim, Analytica Chimica Acta. 2005; 545, 158.

M.H. Mashhadizadeh, A. Mostafavi, H. Allah-Abadi, I. Sheikhshoai, Sensors and Actuators B, 2006; 113, 930.

C. Yang, Y. Chai, R. Yuan, J. Guo, F. Jia, Analytical Sciences, 2012; 28, 275.

Q. Zhao, Y. Chai, R. Yuan, T. Zhang, C. Yang, Materials Science and Engineering C, 2012; 32, 1352.

M. Ghaedi Materials Science and Engineering C, 2012; 32, 2274.

M. R. Ganjali, H. Khoshsafar, F. Faridbod, A. Shirzadmehr, M. Javanbakht, P. Norouzi, Electroanalysis, 2009;21, 2175.